Stator thickness | 18 mm | tw |
Number of phases | 3 | nphase |
Number of coils per phase | 5 | q |
Total number of coils in stator | 15 | coil_num |
Number of turns per coil | 78 | Nc |
Copper wire diameter | 1.4 mm | dc |
Number of wires at hand | 2 | No_wires_at_hand |
Winding fill factor | 0.58 | kf |
Copper wire cross-sectional area | 3.08 mm2 | sc |
Copper wire cross-sectional area (Calculated) | 2.88207 mm² | sc_theor |
Copper wire cross-sectional area of a sinlge wire | 1.54 mm² | sc_multi_wires |
Copper wire diameter (Calculated) | 1.9161 mm | dc_theor |
Coil leg width | 23.0115 mm | wc |
Average length of coil turn | 278.483 mm | lavg |
Stator nominal temperature | 102.179 C° | tc_real |
Stator surface area | 1922.49 cm² | stator_surface_area |
Heat coefficient | 0.368276 | cq_real |
Current density | 5.61443 A | Jmax_real |
Resistivity of copper at nominal temperature | 2.23817E-8 Ohm.m | pt |
Resistance of a single coil | 0.157846 Ohm | Rc |
Phase resistance | 0.789231 Ohm | Rphase |
Phase inductance | 0.00294122 H | Ls |
Nagaoka constant | 0.224411 | Kn |
Winding coefficient | 0.617341 | kw |
Volume of a single coil | 115349 mm3 | coil_volume |
Weight of a single coil | 613.446 g | coil_weight_constr |
Coil hole at Ravg | 29 mm | coil_hole_Ravg |
Coil hole at Rin | 8 mm | coil_hole_Rin_constr |
Coil hole at Rout | 50 mm | coil_hole_Rout_constr |
Coil mass for construction | 9.81513 kgr | mcu_constr |
RMS flux linkage of phase A | 0.0348881 Wb | FluxRmsA |
RMS flux linkage of phase B | 0.0343372 Wb | FluxRmsB |
RMS flux linkage of phase C | 0.0346317 Wb | FluxRmsC |
EMF at the cut-in wind speed (Calculated) | 20.528 V | EMF_cut_in |
EMF at the nominal wind speed (Calculated) | 41.3202 V | EMF_nom |
RMS of EMF of phase A (Flux Linkage) | 50.2326 V | V_rmsA |
RMS of EMF of phase B (Flux Linkage) | 50.3836 V | V_rmsB |
RMS of EMF of phase C (Flux Linkage) | 50.3085 V | V_rmsC |
Current at the nominal wind speed | 17.2924 A | Iac_nom |
Terminal voltage at the nominal wind speed | 26.8147 V | V_term_line |
Nominal frequency | 46.6059 Hz | fnom |
Generator power (Calculated) | 1391.07 W | Pnom |
Generator power (Torque) | 1922.98 W | PelN_Torque_x |
Electromagnetic power (Torque) | 2635.09 W | PHMN_Torque_x |
Copper losses (Calculated) | 708.007 W | Pcopper |
Copper losses (Torque) | 708.007 W | PcopperN_Torque_x |
Eddy current losses (Torque) | 4.108 W | PeddyN_Torque_x |
Generator efficiency (Torque) | 0.720373 | efftotalN_Torque_x |
Generator efficiency (Calculated) | 0.645751 | efficiency_real |
AC Power at the rectifier (Calculated) | 1251.97 W | Pnom_rect |
AC Power at the rectifier (Torque) | 1730.68 W | PelN_Torque_x_rect |
DC Power at the batteries (Calculated) | 1126.77 W | Pnom_dc |
DC Power at the batteries (Torque) | 1557.61 W | PelN_Torque_x_dc |