Stator thickness | 13 mm | tw |
Number of phases | 3 | nphase |
Number of coils per phase | 3 | q |
Total number of coils in stator | 9 | coil_num |
Number of turns per coil | 108 | Nc |
Copper wire diameter | 1.6 mm | dc |
Number of wires at hand | 1 | No_wires_at_hand |
Winding fill factor | 0.57 | kf |
Copper wire cross-sectional area | 2.01 mm2 | sc |
Copper wire cross-sectional area (Calculated) | 1.9496 mm² | sc_theor |
Copper wire cross-sectional area of a sinlge wire | 2.01 mm² | sc_multi_wires |
Copper wire diameter (Calculated) | 1.57593 mm | dc_theor |
Coil leg width | 29.2955 mm | wc |
Average length of coil turn | 243.988 mm | lavg |
Stator nominal temperature | 71.493 C° | tc_real |
Stator surface area | 1286.6 cm² | stator_surface_area |
Heat coefficient | 0.253422 | cq_real |
Current density | 5.81969 A | Jmax_real |
Resistivity of copper at nominal temperature | 2.01956E-8 Ohm.m | pt |
Resistance of a single coil | 0.26476 Ohm | Rc |
Phase resistance | 0.79428 Ohm | Rphase |
Phase inductance | 0.00275192 H | Ls |
Nagaoka constant | 0.171741 | Kn |
Winding coefficient | 0.95 | kw |
Volume of a single coil | 92920.9 mm3 | coil_volume |
Weight of a single coil | 482.275 g | coil_weight_constr |
Coil hole at Ravg | 30 mm | coil_hole_Ravg |
Coil hole at Rin | 30 mm | coil_hole_Rin_constr |
Coil hole at Rout | 30 mm | coil_hole_Rout_constr |
Coil mass for construction | 4.82275 kgr | mcu_constr |
RMS flux linkage of phase A | 0.0650742 Wb | FluxRmsA |
RMS flux linkage of phase B | 0.0640706 Wb | FluxRmsB |
RMS flux linkage of phase C | 0.064773 Wb | FluxRmsC |
EMF at the cut-in wind speed (Calculated) | 20.528 V | EMF_cut_in |
EMF at the nominal wind speed (Calculated) | 30.2992 V | EMF_nom |
RMS of EMF of phase A (Flux Linkage) | 29.9828 V | V_rmsA |
RMS of EMF of phase B (Flux Linkage) | 30.1844 V | V_rmsB |
RMS of EMF of phase C (Flux Linkage) | 30.0167 V | V_rmsC |
Current at the nominal wind speed | 11.6976 A | Iac_nom |
Terminal voltage at the nominal wind speed | 20.528 V | V_term_line |
Nominal frequency | 24.7132 Hz | fnom |
Generator power (Calculated) | 720.384 W | Pnom |
Generator power (Torque) | 693.842 W | PelN_Torque_x |
Electromagnetic power (Torque) | 1021.6 W | PHMN_Torque_x |
Copper losses (Calculated) | 326.052 W | Pcopper |
Copper losses (Torque) | 326.052 W | PcopperN_Torque_x |
Eddy current losses (Torque) | 1.70914 W | PeddyN_Torque_x |
Generator efficiency (Torque) | 0.670237 | efftotalN_Torque_x |
Generator efficiency (Calculated) | 0.676236 | efficiency_real |
AC Power at the rectifier (Calculated) | 720.384 W | Pnom_rect |
AC Power at the rectifier (Torque) | 693.842 W | PelN_Torque_x_rect |
DC Power at the batteries (Calculated) | 648.346 W | Pnom_dc |
DC Power at the batteries (Torque) | 624.458 W | PelN_Torque_x_dc |