Stator thickness | 14 mm | tw |
Number of phases | 3 | nphase |
Number of coils per phase | 4 | q |
Total number of coils in stator | 12 | coil_num |
Number of turns per coil | 76 | Nc |
Copper wire diameter | 1.4 mm | dc |
Number of wires at hand | 1 | No_wires_at_hand |
Winding fill factor | 0.52 | kf |
Copper wire cross-sectional area | 1.54 mm2 | sc |
Copper wire cross-sectional area (Calculated) | 1.4992 mm² | sc_theor |
Copper wire cross-sectional area of a sinlge wire | 1.54 mm² | sc_multi_wires |
Copper wire diameter (Calculated) | 1.38196 mm | dc_theor |
Coil leg width | 16.2377 mm | wc |
Average length of coil turn | 224.078 mm | lavg |
Stator nominal temperature | 44.5089 C° | tc_real |
Stator surface area | 873.244 cm² | stator_surface_area |
Heat coefficient | 0.127071 | cq_real |
Current density | 4.38078 A | Jmax_real |
Resistivity of copper at nominal temperature | 1.83724E-8 Ohm.m | pt |
Resistance of a single coil | 0.20317 Ohm | Rc |
Phase resistance | 0.812678 Ohm | Rphase |
Phase inductance | 0.00187787 H | Ls |
Nagaoka constant | 0.226624 | Kn |
Winding coefficient | 0.95 | kw |
Volume of a single coil | 50939.2 mm3 | coil_volume |
Weight of a single coil | 240.632 g | coil_weight_constr |
Coil hole at Ravg | 50 mm | coil_hole_Ravg |
Coil hole at Rin | 36.8344 mm | coil_hole_Rin_constr |
Coil hole at Rout | 62.8213 mm | coil_hole_Rout_constr |
Coil mass for construction | 3.12821 kgr | mcu_constr |
RMS flux linkage of phase A | 0.0251736 Wb | FluxRmsA |
RMS flux linkage of phase B | 0.0246213 Wb | FluxRmsB |
RMS flux linkage of phase C | 0.0250407 Wb | FluxRmsC |
EMF at the cut-in wind speed (Calculated) | 20.528 V | EMF_cut_in |
EMF at the nominal wind speed (Calculated) | 33.6229 V | EMF_nom |
RMS of EMF of phase A (Flux Linkage) | 28.3813 V | V_rmsA |
RMS of EMF of phase B (Flux Linkage) | 28.5907 V | V_rmsB |
RMS of EMF of phase C (Flux Linkage) | 28.4808 V | V_rmsC |
Current at the nominal wind speed | 6.7464 A | Iac_nom |
Terminal voltage at the nominal wind speed | 26.8147 V | V_term_line |
Nominal frequency | 45.6416 Hz | fnom |
Generator power (Calculated) | 542.708 W | Pnom |
Generator power (Torque) | 445.99 W | PelN_Torque_x |
Electromagnetic power (Torque) | 557.967 W | PHMN_Torque_x |
Copper losses (Calculated) | 110.964 W | Pcopper |
Copper losses (Torque) | 110.964 W | PcopperN_Torque_x |
Eddy current losses (Torque) | 1.01248 W | PeddyN_Torque_x |
Generator efficiency (Torque) | 0.769132 | efftotalN_Torque_x |
Generator efficiency (Calculated) | 0.798445 | efficiency_real |
AC Power at the rectifier (Calculated) | 488.437 W | Pnom_rect |
AC Power at the rectifier (Torque) | 401.391 W | PelN_Torque_x_rect |
DC Power at the batteries (Calculated) | 439.593 W | Pnom_dc |
DC Power at the batteries (Torque) | 361.252 W | PelN_Torque_x_dc |