Stator thickness | 16 mm | tw |
Number of phases | 3 | nphase |
Number of coils per phase | 4 | q |
Total number of coils in stator | 12 | coil_num |
Number of turns per coil | 27 | Nc |
Copper wire diameter | 1.6 mm | dc |
Number of wires at hand | 3 | No_wires_at_hand |
Winding fill factor | 0.48 | kf |
Copper wire cross-sectional area | 6.03 mm2 | sc |
Copper wire cross-sectional area (Calculated) | 5.62769 mm² | sc_theor |
Copper wire cross-sectional area of a sinlge wire | 2.01 mm² | sc_multi_wires |
Copper wire diameter (Calculated) | 2.6775 mm | dc_theor |
Coil leg width | 21.4112 mm | wc |
Average length of coil turn | 203.554 mm | lavg |
Stator nominal temperature | 49.9704 C° | tc_real |
Stator surface area | 1046 cm² | stator_surface_area |
Heat coefficient | 0.155545 | cq_real |
Current density | 4.66641 A | Jmax_real |
Resistivity of copper at nominal temperature | 1.8788E-8 Ohm.m | pt |
Resistance of a single coil | 0.017124 Ohm | Rc |
Phase resistance | 0.0684961 Ohm | Rphase |
Phase inductance | 0.000181616 H | Ls |
Nagaoka constant | 0.240507 | Kn |
Winding coefficient | 0.95 | kw |
Volume of a single coil | 69733.4 mm3 | coil_volume |
Weight of a single coil | 318.223 g | coil_weight_constr |
Coil hole at Ravg | 25 mm | coil_hole_Ravg |
Coil hole at Rin | 11.9383 mm | coil_hole_Rin_constr |
Coil hole at Rout | 38.0293 mm | coil_hole_Rout_constr |
Coil mass for construction | 4.13691 kgr | mcu_constr |
RMS flux linkage of phase A | 0.0155879 Wb | FluxRmsA |
RMS flux linkage of phase B | 0.0151851 Wb | FluxRmsB |
RMS flux linkage of phase C | 0.0155269 Wb | FluxRmsC |
EMF at the cut-in wind speed (Calculated) | 6.415 V | EMF_cut_in |
EMF at the nominal wind speed (Calculated) | 17.2642 V | EMF_nom |
RMS of EMF of phase A (Flux Linkage) | 15.9896 V | V_rmsA |
RMS of EMF of phase B (Flux Linkage) | 16.2321 V | V_rmsB |
RMS of EMF of phase C (Flux Linkage) | 16.0196 V | V_rmsC |
Current at the nominal wind speed | 28.1384 A | Iac_nom |
Terminal voltage at the nominal wind speed | 14.113 V | V_term_line |
Nominal frequency | 41.7389 Hz | fnom |
Generator power (Calculated) | 1191.35 W | Pnom |
Generator power (Torque) | 1079.74 W | PelN_Torque_x |
Electromagnetic power (Torque) | 1261.07 W | PHMN_Torque_x |
Copper losses (Calculated) | 162.7 W | Pcopper |
Copper losses (Torque) | 162.7 W | PcopperN_Torque_x |
Eddy current losses (Torque) | 18.6292 W | PeddyN_Torque_x |
Generator efficiency (Torque) | 0.840078 | efftotalN_Torque_x |
Generator efficiency (Calculated) | 0.81932 | efficiency_real |
AC Power at the rectifier (Calculated) | 1072.22 W | Pnom_rect |
AC Power at the rectifier (Torque) | 971.765 W | PelN_Torque_x_rect |
DC Power at the batteries (Calculated) | 964.997 W | Pnom_dc |
DC Power at the batteries (Torque) | 874.589 W | PelN_Torque_x_dc |