Stator thickness | 12 mm | tw |
Number of phases | 3 | nphase |
Number of coils per phase | 3 | q |
Total number of coils in stator | 9 | coil_num |
Number of turns per coil | 49 | Nc |
Copper wire diameter | 1.5 mm | dc |
Number of wires at hand | 2 | No_wires_at_hand |
Winding fill factor | 0.55 | kf |
Copper wire cross-sectional area | 3.54 mm2 | sc |
Copper wire cross-sectional area (Calculated) | 3.13974 mm² | sc_theor |
Copper wire cross-sectional area of a sinlge wire | 1.77 mm² | sc_multi_wires |
Copper wire diameter (Calculated) | 1.99992 mm | dc_theor |
Coil leg width | 26.2818 mm | wc |
Average length of coil turn | 234.525 mm | lavg |
Stator nominal temperature | 72.7842 C° | tc_real |
Stator surface area | 1109.47 cm² | stator_surface_area |
Heat coefficient | 0.25874 | cq_real |
Current density | 6.20852 A | Jmax_real |
Resistivity of copper at nominal temperature | 2.0341E-8 Ohm.m | pt |
Resistance of a single coil | 0.0660321 Ohm | Rc |
Phase resistance | 0.198096 Ohm | Rphase |
Phase inductance | 0.000562964 H | Ls |
Nagaoka constant | 0.170518 | Kn |
Winding coefficient | 0.95 | kw |
Volume of a single coil | 73964.9 mm3 | coil_volume |
Weight of a single coil | 378.53 g | coil_weight_constr |
Coil hole at Ravg | 30 mm | coil_hole_Ravg |
Coil hole at Rin | 30 mm | coil_hole_Rin_constr |
Coil hole at Rout | 30 mm | coil_hole_Rout_constr |
Coil mass for construction | 3.7853 kgr | mcu_constr |
RMS flux linkage of phase A | 0.0326318 Wb | FluxRmsA |
RMS flux linkage of phase B | 0.0322849 Wb | FluxRmsB |
RMS flux linkage of phase C | 0.032568 Wb | FluxRmsC |
EMF at the cut-in wind speed (Calculated) | 10.264 V | EMF_cut_in |
EMF at the nominal wind speed (Calculated) | 16.1264 V | EMF_nom |
RMS of EMF of phase A (Flux Linkage) | 15.9341 V | V_rmsA |
RMS of EMF of phase B (Flux Linkage) | 15.9393 V | V_rmsB |
RMS of EMF of phase C (Flux Linkage) | 15.9366 V | V_rmsC |
Current at the nominal wind speed | 21.9782 A | Iac_nom |
Terminal voltage at the nominal wind speed | 11.2904 V | V_term_line |
Nominal frequency | 26.1245 Hz | fnom |
Generator power (Calculated) | 744.427 W | Pnom |
Generator power (Torque) | 745.968 W | PelN_Torque_x |
Electromagnetic power (Torque) | 1036.05 W | PHMN_Torque_x |
Copper losses (Calculated) | 287.065 W | Pcopper |
Copper losses (Torque) | 287.065 W | PcopperN_Torque_x |
Eddy current losses (Torque) | 3.01717 W | PeddyN_Torque_x |
Generator efficiency (Torque) | 0.710216 | efftotalN_Torque_x |
Generator efficiency (Calculated) | 0.705623 | efficiency_real |
AC Power at the rectifier (Calculated) | 669.984 W | Pnom_rect |
AC Power at the rectifier (Torque) | 671.371 W | PelN_Torque_x_rect |
DC Power at the batteries (Calculated) | 602.986 W | Pnom_dc |
DC Power at the batteries (Torque) | 604.234 W | PelN_Torque_x_dc |