Stator thickness | 13 mm | tw |
Number of phases | 3 | nphase |
Number of coils per phase | 5 | q |
Total number of coils in stator | 15 | coil_num |
Number of turns per coil | 183 | Nc |
Copper wire diameter | 1.32 mm | dc |
Number of wires at hand | 1 | No_wires_at_hand |
Winding fill factor | 0.65 | kf |
Copper wire cross-sectional area | 1.37 mm2 | sc |
Copper wire cross-sectional area (Calculated) | 1.2521 mm² | sc_theor |
Copper wire cross-sectional area of a sinlge wire | 1.37 mm² | sc_multi_wires |
Copper wire diameter (Calculated) | 1.26294 mm | dc_theor |
Coil leg width | 29.9665 mm | wc |
Average length of coil turn | 228.076 mm | lavg |
Stator nominal temperature | 48.9831 C° | tc_real |
Stator surface area | 2050.39 cm² | stator_surface_area |
Heat coefficient | 0.150533 | cq_real |
Current density | 4.38691 A | Jmax_real |
Resistivity of copper at nominal temperature | 1.86986E-8 Ohm.m | pt |
Resistance of a single coil | 0.569664 Ohm | Rc |
Phase resistance | 2.84832 Ohm | Rphase |
Phase inductance | 0.0117269 H | Ls |
Nagaoka constant | 0.175024 | Kn |
Winding coefficient | 0.95 | kw |
Volume of a single coil | 88850.3 mm3 | coil_volume |
Weight of a single coil | 516.784 g | coil_weight_constr |
Coil hole at Ravg | 25 mm | coil_hole_Ravg |
Coil hole at Rin | 14.358 mm | coil_hole_Rin_constr |
Coil hole at Rout | 35.6887 mm | coil_hole_Rout_constr |
Coil mass for construction | 8.26854 kgr | mcu_constr |
RMS flux linkage of phase A | 0.10462 Wb | FluxRmsA |
RMS flux linkage of phase B | 0.102179 Wb | FluxRmsB |
RMS flux linkage of phase C | 0.104033 Wb | FluxRmsC |
EMF at the cut-in wind speed (Calculated) | 64.15 V | EMF_cut_in |
EMF at the nominal wind speed (Calculated) | 171.067 V | EMF_nom |
RMS of EMF of phase A (Flux Linkage) | 171.126 V | V_rmsA |
RMS of EMF of phase B (Flux Linkage) | 173.757 V | V_rmsB |
RMS of EMF of phase C (Flux Linkage) | 171.649 V | V_rmsC |
Current at the nominal wind speed | 6.01007 A | Iac_nom |
Terminal voltage at the nominal wind speed | 352.825 V | V_term_line |
Nominal frequency | 53.0786 Hz | fnom |
Generator power (Calculated) | 2691.69 W | Pnom |
Generator power (Torque) | 2702.45 W | PelN_Torque_x |
Electromagnetic power (Torque) | 3018.02 W | PHMN_Torque_x |
Copper losses (Calculated) | 308.652 W | Pcopper |
Copper losses (Torque) | 308.652 W | PcopperN_Torque_x |
Eddy current losses (Torque) | 6.92099 W | PeddyN_Torque_x |
Generator efficiency (Torque) | 0.884765 | efftotalN_Torque_x |
Generator efficiency (Calculated) | 0.876154 | efficiency_real |
AC Power at the rectifier (Calculated) | 2422.52 W | Pnom_rect |
AC Power at the rectifier (Torque) | 2432.21 W | PelN_Torque_x_rect |
DC Power at the batteries (Calculated) | 2398.29 W | Pnom_dc |
DC Power at the batteries (Torque) | 2407.88 W | PelN_Torque_x_dc |