Stator thickness | 13 mm | tw |
Number of phases | 3 | nphase |
Number of coils per phase | 5 | q |
Total number of coils in stator | 15 | coil_num |
Number of turns per coil | 244 | Nc |
Copper wire diameter | 1 mm | dc |
Number of wires at hand | 1 | No_wires_at_hand |
Winding fill factor | 0.65 | kf |
Copper wire cross-sectional area | 0.79 mm2 | sc |
Copper wire cross-sectional area (Calculated) | 0.751259 mm² | sc_theor |
Copper wire cross-sectional area of a sinlge wire | 0.79 mm² | sc_multi_wires |
Copper wire diameter (Calculated) | 0.978273 mm | dc_theor |
Coil leg width | 23.04 mm | wc |
Average length of coil turn | 208.672 mm | lavg |
Stator nominal temperature | 78.2217 C° | tc_real |
Stator surface area | 1442.33 cm² | stator_surface_area |
Heat coefficient | 0.280589 | cq_real |
Current density | 5.70576 A | Jmax_real |
Resistivity of copper at nominal temperature | 2.06033E-8 Ohm.m | pt |
Resistance of a single coil | 1.32789 Ohm | Rc |
Phase resistance | 6.63947 Ohm | Rphase |
Phase inductance | 0.0199021 H | Ls |
Nagaoka constant | 0.199602 | Kn |
Winding coefficient | 0.95 | kw |
Volume of a single coil | 62501.2 mm3 | coil_volume |
Weight of a single coil | 362.546 g | coil_weight_constr |
Coil hole at Ravg | 25 mm | coil_hole_Ravg |
Coil hole at Rin | 14.3491 mm | coil_hole_Rin_constr |
Coil hole at Rout | 35.6686 mm | coil_hole_Rout_constr |
Coil mass for construction | 5.80073 kgr | mcu_constr |
RMS flux linkage of phase A | 0.133226 Wb | FluxRmsA |
RMS flux linkage of phase B | 0.13071 Wb | FluxRmsB |
RMS flux linkage of phase C | 0.132667 Wb | FluxRmsC |
EMF at the cut-in wind speed (Calculated) | 85.5334 V | EMF_cut_in |
EMF at the nominal wind speed (Calculated) | 228.089 V | EMF_nom |
RMS of EMF of phase A (Flux Linkage) | 218.475 V | V_rmsA |
RMS of EMF of phase B (Flux Linkage) | 219.812 V | V_rmsB |
RMS of EMF of phase C (Flux Linkage) | 218.735 V | V_rmsC |
Current at the nominal wind speed | 4.50755 A | Iac_nom |
Terminal voltage at the nominal wind speed | 352.825 V | V_term_line |
Nominal frequency | 53.0786 Hz | fnom |
Generator power (Calculated) | 2619.96 W | Pnom |
Generator power (Torque) | 2481.85 W | PelN_Torque_x |
Electromagnetic power (Torque) | 2890.29 W | PHMN_Torque_x |
Copper losses (Calculated) | 404.703 W | Pcopper |
Copper losses (Torque) | 404.703 W | PcopperN_Torque_x |
Eddy current losses (Torque) | 3.73913 W | PeddyN_Torque_x |
Generator efficiency (Torque) | 0.849292 | efftotalN_Torque_x |
Generator efficiency (Calculated) | 0.851816 | efficiency_real |
AC Power at the rectifier (Calculated) | 2357.97 W | Pnom_rect |
AC Power at the rectifier (Torque) | 2233.66 W | PelN_Torque_x_rect |
DC Power at the batteries (Calculated) | 2334.39 W | Pnom_dc |
DC Power at the batteries (Torque) | 2211.32 W | PelN_Torque_x_dc |