Stator thickness | 13 mm | tw |
Number of phases | 3 | nphase |
Number of coils per phase | 5 | q |
Total number of coils in stator | 15 | coil_num |
Number of turns per coil | 244 | Nc |
Copper wire diameter | 1.12 mm | dc |
Number of wires at hand | 1 | No_wires_at_hand |
Winding fill factor | 0.65 | kf |
Copper wire cross-sectional area | 0.99 mm2 | sc |
Copper wire cross-sectional area (Calculated) | 0.901511 mm² | sc_theor |
Copper wire cross-sectional area of a sinlge wire | 0.99 mm² | sc_multi_wires |
Copper wire diameter (Calculated) | 1.07164 mm | dc_theor |
Coil leg width | 28.8729 mm | wc |
Average length of coil turn | 225.012 mm | lavg |
Stator nominal temperature | 51.5925 C° | tc_real |
Stator surface area | 1949.02 cm² | stator_surface_area |
Heat coefficient | 0.163657 | cq_real |
Current density | 4.55308 A | Jmax_real |
Resistivity of copper at nominal temperature | 1.88721E-8 Ohm.m | pt |
Resistance of a single coil | 1.0466 Ohm | Rc |
Phase resistance | 5.23298 Ohm | Rphase |
Phase inductance | 0.0206921 H | Ls |
Nagaoka constant | 0.178479 | Kn |
Winding coefficient | 0.95 | kw |
Volume of a single coil | 84457.6 mm3 | coil_volume |
Weight of a single coil | 489.907 g | coil_weight_constr |
Coil hole at Ravg | 25 mm | coil_hole_Ravg |
Coil hole at Rin | 14.3567 mm | coil_hole_Rin_constr |
Coil hole at Rout | 35.6859 mm | coil_hole_Rout_constr |
Coil mass for construction | 7.83851 kgr | mcu_constr |
RMS flux linkage of phase A | 0.138565 Wb | FluxRmsA |
RMS flux linkage of phase B | 0.135875 Wb | FluxRmsB |
RMS flux linkage of phase C | 0.137953 Wb | FluxRmsC |
EMF at the cut-in wind speed (Calculated) | 85.5334 V | EMF_cut_in |
EMF at the nominal wind speed (Calculated) | 228.089 V | EMF_nom |
RMS of EMF of phase A (Flux Linkage) | 227.48 V | V_rmsA |
RMS of EMF of phase B (Flux Linkage) | 229.678 V | V_rmsB |
RMS of EMF of phase C (Flux Linkage) | 227.91 V | V_rmsC |
Current at the nominal wind speed | 4.50755 A | Iac_nom |
Terminal voltage at the nominal wind speed | 352.825 V | V_term_line |
Nominal frequency | 53.0786 Hz | fnom |
Generator power (Calculated) | 2691.73 W | Pnom |
Generator power (Torque) | 2667.04 W | PelN_Torque_x |
Electromagnetic power (Torque) | 2990.91 W | PHMN_Torque_x |
Copper losses (Calculated) | 318.972 W | Pcopper |
Copper losses (Torque) | 318.972 W | PcopperN_Torque_x |
Eddy current losses (Torque) | 4.90582 W | PeddyN_Torque_x |
Generator efficiency (Torque) | 0.881207 | efftotalN_Torque_x |
Generator efficiency (Calculated) | 0.876364 | efficiency_real |
AC Power at the rectifier (Calculated) | 2422.56 W | Pnom_rect |
AC Power at the rectifier (Torque) | 2400.33 W | PelN_Torque_x_rect |
DC Power at the batteries (Calculated) | 2398.33 W | Pnom_dc |
DC Power at the batteries (Torque) | 2376.33 W | PelN_Torque_x_dc |