Stator thickness | 15 mm | tw |
Number of phases | 3 | nphase |
Number of coils per phase | 6 | q |
Total number of coils in stator | 18 | coil_num |
Number of turns per coil | 38 | Nc |
Copper wire diameter | 1.5 mm | dc |
Number of wires at hand | 2 | No_wires_at_hand |
Winding fill factor | 0.5 | kf |
Copper wire cross-sectional area | 3.54 mm2 | sc |
Copper wire cross-sectional area (Calculated) | 3.20501 mm² | sc_theor |
Copper wire cross-sectional area of a sinlge wire | 1.77 mm² | sc_multi_wires |
Copper wire diameter (Calculated) | 2.0206 mm | dc_theor |
Coil leg width | 18.1154 mm | wc |
Average length of coil turn | 170.656 mm | lavg |
Stator nominal temperature | 47.2245 C° | tc_real |
Stator surface area | 1112.94 cm² | stator_surface_area |
Heat coefficient | 0.141464 | cq_real |
Current density | 4.52685 A | Jmax_real |
Resistivity of copper at nominal temperature | 1.85928E-8 Ohm.m | pt |
Resistance of a single coil | 0.0340601 Ohm | Rc |
Phase resistance | 0.20436 Ohm | Rphase |
Phase inductance | 0.000436073 H | Ls |
Nagaoka constant | 0.259233 | Kn |
Winding coefficient | 0.95 | kw |
Volume of a single coil | 46372.3 mm3 | coil_volume |
Weight of a single coil | 216.034 g | coil_weight_constr |
Coil hole at Ravg | 25 mm | coil_hole_Ravg |
Coil hole at Rin | 18.0401 mm | coil_hole_Rin_constr |
Coil hole at Rout | 31.9774 mm | coil_hole_Rout_constr |
Coil mass for construction | 4.10464 kgr | mcu_constr |
RMS flux linkage of phase A | 0.0176627 Wb | FluxRmsA |
RMS flux linkage of phase B | 0.0171758 Wb | FluxRmsB |
RMS flux linkage of phase C | 0.0175971 Wb | FluxRmsC |
EMF at the cut-in wind speed (Calculated) | 8.55334 V | EMF_cut_in |
EMF at the nominal wind speed (Calculated) | 55.3031 V | EMF_nom |
RMS of EMF of phase A (Flux Linkage) | 52.3016 V | V_rmsA |
RMS of EMF of phase B (Flux Linkage) | 53.0776 V | V_rmsB |
RMS of EMF of phase C (Flux Linkage) | 52.3725 V | V_rmsC |
Current at the nominal wind speed | 16.025 A | Iac_nom |
Terminal voltage at the nominal wind speed | 45.1616 V | V_term_line |
Nominal frequency | 80.4815 Hz | fnom |
Generator power (Calculated) | 2171.15 W | Pnom |
Generator power (Torque) | 2192.68 W | PelN_Torque_x |
Electromagnetic power (Torque) | 2380.78 W | PHMN_Torque_x |
Copper losses (Calculated) | 157.44 W | Pcopper |
Copper losses (Torque) | 157.44 W | PcopperN_Torque_x |
Eddy current losses (Torque) | 30.6549 W | PeddyN_Torque_x |
Generator efficiency (Torque) | 0.869791 | efftotalN_Torque_x |
Generator efficiency (Calculated) | 0.817601 | efficiency_real |
AC Power at the rectifier (Calculated) | 1954.03 W | Pnom_rect |
AC Power at the rectifier (Torque) | 1973.42 W | PelN_Torque_x_rect |
DC Power at the batteries (Calculated) | 1758.63 W | Pnom_dc |
DC Power at the batteries (Torque) | 1776.07 W | PelN_Torque_x_dc |