Stator thickness | 15 mm | tw |
Number of phases | 3 | nphase |
Number of coils per phase | 4 | q |
Total number of coils in stator | 12 | coil_num |
Number of turns per coil | 22 | Nc |
Copper wire diameter | 1.5 mm | dc |
Number of wires at hand | 2 | No_wires_at_hand |
Winding fill factor | 0.75 | kf |
Copper wire cross-sectional area | 3.54 mm2 | sc |
Copper wire cross-sectional area (Calculated) | 3.35473 mm² | sc_theor |
Copper wire cross-sectional area of a sinlge wire | 1.77 mm² | sc_multi_wires |
Copper wire diameter (Calculated) | 2.06725 mm | dc_theor |
Coil leg width | 6.92267 mm | wc |
Average length of coil turn | 173.737 mm | lavg |
Stator nominal temperature | 112.293 C° | tc_real |
Stator surface area | 288.654 cm² | stator_surface_area |
Heat coefficient | 0.40197 | cq_real |
Current density | 5.68598 A | Jmax_real |
Resistivity of copper at nominal temperature | 2.21035E-8 Ohm.m | pt |
Resistance of a single coil | 0.0238657 Ohm | Rc |
Phase resistance | 0.0954627 Ohm | Rphase |
Phase inductance | 0.000124593 H | Ls |
Nagaoka constant | 0.319811 | Kn |
Winding coefficient | 0.95 | kw |
Volume of a single coil | 18040.9 mm3 | coil_volume |
Weight of a single coil | 131.961 g | coil_weight_constr |
Coil hole at Ravg | 30 mm | coil_hole_Ravg |
Coil hole at Rin | 30 mm | coil_hole_Rin_constr |
Coil hole at Rout | 30 mm | coil_hole_Rout_constr |
Coil mass for construction | 1.71549 kgr | mcu_constr |
RMS flux linkage of phase A | 0.0118785 Wb | FluxRmsA |
RMS flux linkage of phase B | 0.0116544 Wb | FluxRmsB |
RMS flux linkage of phase C | 0.0118624 Wb | FluxRmsC |
EMF at the cut-in wind speed (Calculated) | 10.264 V | EMF_cut_in |
EMF at the nominal wind speed (Calculated) | 13.5232 V | EMF_nom |
RMS of EMF of phase A (Flux Linkage) | 10.738 V | V_rmsA |
RMS of EMF of phase B (Flux Linkage) | 10.7544 V | V_rmsB |
RMS of EMF of phase C (Flux Linkage) | 10.7383 V | V_rmsC |
Current at the nominal wind speed | 20.1284 A | Iac_nom |
Terminal voltage at the nominal wind speed | 11.2904 V | V_term_line |
Nominal frequency | 36.6839 Hz | fnom |
Generator power (Calculated) | 681.772 W | Pnom |
Generator power (Torque) | 506.117 W | PelN_Torque_x |
Electromagnetic power (Torque) | 626.608 W | PHMN_Torque_x |
Copper losses (Calculated) | 116.03 W | Pcopper |
Copper losses (Torque) | 116.03 W | PcopperN_Torque_x |
Eddy current losses (Torque) | 4.46091 W | PeddyN_Torque_x |
Generator efficiency (Torque) | 0.794616 | efftotalN_Torque_x |
Generator efficiency (Calculated) | 0.825212 | efficiency_real |
AC Power at the rectifier (Calculated) | 613.595 W | Pnom_rect |
AC Power at the rectifier (Torque) | 455.505 W | PelN_Torque_x_rect |
DC Power at the batteries (Calculated) | 552.235 W | Pnom_dc |
DC Power at the batteries (Torque) | 409.955 W | PelN_Torque_x_dc |