Stator thickness | 17 mm | tw |
Number of phases | 3 | nphase |
Number of coils per phase | 3 | q |
Total number of coils in stator | 9 | coil_num |
Number of turns per coil | 66 | Nc |
Copper wire diameter | 1.7 mm | dc |
Number of wires at hand | 2 | No_wires_at_hand |
Winding fill factor | 0.55 | kf |
Copper wire cross-sectional area | 4.54 mm2 | sc |
Copper wire cross-sectional area (Calculated) | 4.14698 mm² | sc_theor |
Copper wire cross-sectional area of a sinlge wire | 2.27 mm² | sc_multi_wires |
Copper wire diameter (Calculated) | 2.29843 mm | dc_theor |
Coil leg width | 32.0471 mm | wc |
Average length of coil turn | 240.628 mm | lavg |
Stator nominal temperature | 80.8345 C° | tc_real |
Stator surface area | 1388.05 cm² | stator_surface_area |
Heat coefficient | 0.290795 | cq_real |
Current density | 5.48059 A | Jmax_real |
Resistivity of copper at nominal temperature | 2.07086E-8 Ohm.m | pt |
Resistance of a single coil | 0.0724411 Ohm | Rc |
Phase resistance | 0.217323 Ohm | Rphase |
Phase inductance | 0.000912307 H | Ls |
Nagaoka constant | 0.20497 | Kn |
Winding coefficient | 0.95 | kw |
Volume of a single coil | 131094 mm3 | coil_volume |
Weight of a single coil | 664.122 g | coil_weight_constr |
Coil hole at Ravg | 20 mm | coil_hole_Ravg |
Coil hole at Rin | 20 mm | coil_hole_Rin_constr |
Coil hole at Rout | 20 mm | coil_hole_Rout_constr |
Coil mass for construction | 6.64122 kgr | mcu_constr |
RMS flux linkage of phase A | 0.0320777 Wb | FluxRmsA |
RMS flux linkage of phase B | 0.0314438 Wb | FluxRmsB |
RMS flux linkage of phase C | 0.0318002 Wb | FluxRmsC |
EMF at the cut-in wind speed (Calculated) | 10.264 V | EMF_cut_in |
EMF at the nominal wind speed (Calculated) | 17.0933 V | EMF_nom |
RMS of EMF of phase A (Flux Linkage) | 16.469 V | V_rmsA |
RMS of EMF of phase B (Flux Linkage) | 16.6384 V | V_rmsB |
RMS of EMF of phase C (Flux Linkage) | 16.5328 V | V_rmsC |
Current at the nominal wind speed | 24.8819 A | Iac_nom |
Terminal voltage at the nominal wind speed | 11.2904 V | V_term_line |
Nominal frequency | 27.7964 Hz | fnom |
Generator power (Calculated) | 842.779 W | Pnom |
Generator power (Torque) | 839.877 W | PelN_Torque_x |
Electromagnetic power (Torque) | 1247.61 W | PHMN_Torque_x |
Copper losses (Calculated) | 403.64 W | Pcopper |
Copper losses (Torque) | 403.64 W | PcopperN_Torque_x |
Eddy current losses (Torque) | 4.09353 W | PeddyN_Torque_x |
Generator efficiency (Torque) | 0.667061 | efftotalN_Torque_x |
Generator efficiency (Calculated) | 0.663417 | efficiency_real |
AC Power at the rectifier (Calculated) | 758.502 W | Pnom_rect |
AC Power at the rectifier (Torque) | 755.89 W | PelN_Torque_x_rect |
DC Power at the batteries (Calculated) | 682.651 W | Pnom_dc |
DC Power at the batteries (Torque) | 680.301 W | PelN_Torque_x_dc |