Stator thickness | 10 mm | tw |
Number of phases | 3 | nphase |
Number of coils per phase | 2 | q |
Total number of coils in stator | 6 | coil_num |
Number of turns per coil | 73 | Nc |
Copper wire diameter | 1.5 mm | dc |
Number of wires at hand | 1 | No_wires_at_hand |
Winding fill factor | 0.55 | kf |
Copper wire cross-sectional area | 1.77 mm2 | sc |
Copper wire cross-sectional area (Calculated) | 1.57182 mm² | sc_theor |
Copper wire cross-sectional area of a sinlge wire | 1.77 mm² | sc_multi_wires |
Copper wire diameter (Calculated) | 1.41503 mm | dc_theor |
Coil leg width | 23.4927 mm | wc |
Average length of coil turn | 225.767 mm | lavg |
Stator nominal temperature | 61.1417 C° | tc_real |
Stator surface area | 636.466 cm² | stator_surface_area |
Heat coefficient | 0.20875 | cq_real |
Current density | 6.21622 A | Jmax_real |
Resistivity of copper at nominal temperature | 1.96445E-8 Ohm.m | pt |
Resistance of a single coil | 0.182916 Ohm | Rc |
Phase resistance | 0.365832 Ohm | Rphase |
Phase inductance | 0.000846643 H | Ls |
Nagaoka constant | 0.155849 | Kn |
Winding coefficient | 0.65645 | kw |
Volume of a single coil | 53038.9 mm3 | coil_volume |
Weight of a single coil | 267.937 g | coil_weight_constr |
Coil hole at Ravg | 46 mm | coil_hole_Ravg |
Coil hole at Rin | 46 mm | coil_hole_Rin_constr |
Coil hole at Rout | 46 mm | coil_hole_Rout_constr |
Coil mass for construction | 1.87556 kgr | mcu_constr |
RMS flux linkage of phase A | 0.018072 Wb | FluxRmsA |
RMS flux linkage of phase B | 0.017811 Wb | FluxRmsB |
RMS flux linkage of phase C | 0.0180104 Wb | FluxRmsC |
EMF at the cut-in wind speed (Calculated) | 5.132 V | EMF_cut_in |
EMF at the nominal wind speed (Calculated) | 10.1619 V | EMF_nom |
RMS of EMF of phase A (Flux Linkage) | 10.3109 V | V_rmsA |
RMS of EMF of phase B (Flux Linkage) | 10.3728 V | V_rmsB |
RMS of EMF of phase C (Flux Linkage) | 10.3187 V | V_rmsC |
Current at the nominal wind speed | 11.0027 A | Iac_nom |
Terminal voltage at the nominal wind speed | 5.6452 V | V_term_line |
Nominal frequency | 45.8045 Hz | fnom |
Generator power (Calculated) | 186.338 W | Pnom |
Generator power (Torque) | 200.891 W | PelN_Torque_x |
Electromagnetic power (Torque) | 334.297 W | PHMN_Torque_x |
Copper losses (Calculated) | 132.862 W | Pcopper |
Copper losses (Torque) | 132.862 W | PcopperN_Torque_x |
Eddy current losses (Torque) | 0.543617 W | PeddyN_Torque_x |
Generator efficiency (Torque) | 0.580243 | efftotalN_Torque_x |
Generator efficiency (Calculated) | 0.560864 | efficiency_real |
AC Power at the rectifier (Calculated) | 167.704 W | Pnom_rect |
AC Power at the rectifier (Torque) | 180.802 W | PelN_Torque_x_rect |
DC Power at the batteries (Calculated) | 150.933 W | Pnom_dc |
DC Power at the batteries (Torque) | 162.722 W | PelN_Torque_x_dc |